Factory in Hangzhou · ISO 9001 quality system show (JavaScript required) show (JavaScript required)
YUQIUGear reducers & motors
WPE double-stage worm gear reducers — WPEA
  • WPEKA
  • WPEDA
  • WPEDKA
  • WPEO

WPE

WPE double-stage worm gear reducers

Double-stage worm gear reducers combining two WP stages for very low output speeds: ratios from 200 to 900. Ten size combinations from 40-70 to 155-250, output torque up to 6050 N·m.

Sizes (stage centre distances)
40-70 to 155-250 mm (10 combinations)
Ratio
200–900
Input power (1500 r/min)
0.17–11.71 kW
Output torque
250–6050 N·m
Motor power (D versions)
0.12–5.5 kW
Weight (WPEA)
20–462 kg
Lubrication
as WP series: N220–N320 or N320–N460 depending on ambient temperature

Features

  • Ratios 200, 300, 400, 500, 600, 800, 900
  • 10 size combinations: 40-70, 50-80, 60-100, 70-120, 80-135, 80-147, 100-155, 120-175, 135-200, 155-250
  • Input shaft or motor flange (D), motors 0.12–5.5 kW
  • Solid or hollow (K) output shaft
  • Shaft arrangements A, S, O, X; basic WPE and universal WPWE housings
  • Rated output torque is the same for all ratios (input-shaft versions)

Designation

WPWEDKA50-80—600—B

WPWorm reducer, one-piece housing
WUniversal housing (no code — basic)
EDouble stage (EE — multi-stage)
DMotor flange
KHollow output shaft
AShaft arrangement (A/S/O/X)
50-80Stage centre distances
600Ratio
BShaft direction

Versions

WPEA / WPES / WPEO / WPEXInput shaft, solid output shaft; input below/above, output up/down
WPEKA / WPEKSWith hollow output shaft
WPEDA / WPEDS / WPEDO / WPEDXWith motor flange
WPEDKA / WPEDKSWith motor flange and hollow output shaft
WPWE / WPWED / WPWEK / WPWEDK / WPWEKO / WPWEDKODouble-stage versions in the universal W housing
WPEEA / WPEEDOMulti-stage EE versions (shown in product guide)

Technical data

WPE, WPEK, WPEW, WPWEK (A, S, X, O): input shaft power, kW, and output torque, N·m (input 1500 r/min)

SizeP1, kW, i = 200i = 300i = 400i = 500i = 600i = 800i = 900T2, N·m (all ratios)
40-700.480.340.280.250.230.200.17250
50-800.650.510.420.380.310.290.25350
60-1000.950.670.520.440.400.350.33500
70-1201.641.180.910.840.710.580.54840
80-1352.5010751.391.191.080.980.851400
80-1472.792.11.711.471.341.201.061575
100-1553.692.922.412.071.891.691.502100
120-1755.093.913.272.722.532.502.053050
135-2007.225.414.463.833.462.912.713950
155-25011.718.146.005.144.674.073.676050

WPED, WPEDK, WPWED, WPWEDK (motor flange): motor power, kW / output torque, N·m

Sizei = 200i = 300i = 400i = 500i = 600i = 800i = 900
40-700.12 / 630.12 / 880.12 / 1070.12 / 1200.12 / 1300.12 / 1500.12 / 177
50-800.18 / 970.18 / 1240.18 / 1500.18 / 1660.18 / 2030.18 / 2170.18 / 252
60-1000.37 / 1950.37 / 2760.37 / 3560.37 / 4200.37 / 4630.37 / 5290.37 / 561
70-1200.75 / 3840.75 / 5340.75 / 6920.75 / 7500.37 / 4860.37 / 5360.75 / 887
80-1351.5 / 6161.5 / 8801.5 / 11081.5 / 12940.75 / 10100.75 / 10711.5 / 1426
80-1471.5 / 6621.5 / 9021.5 / 12081.5 / 13160.75 / 13000.75 / 13211.5 / 1575
100-1551.5 / 8541.5 / 10791.5 / 13071.5 / 15221.5 / 16671.5 / 18641.5 / 2100
120-1753 / 17983 / 23403 / 27983 / 30502.2 / 25002.2 / 26853 / 3050
135-2004 / 21884 / 29204 / 35434 / 39503 / 39503 / 39504 / 3950
155-2505.5 / 28415.5 / 40875.5 / 55465.5 / 60504 / 60504 / 60505.5 / 6050

Data from the manufacturer’s catalogue. Full selection tables and dimension drawings are in the PDF catalogue.

Drawings

WPEA outline drawing
WPEA outline drawing
Designation structure (double-stage example WPWEDKA50-80-600-B)
Designation structure (double-stage example WPWEDKA50-80-600-B)